Enviro Process Engineering (HK) Co. Ltd.

安和環保工程(香港)有限公司

Home  Contact Us Products
ECOFRESH - ENERGY RECOVERY VENTILATORS

EcoFresh ERV¦³§U©ó³]­pªÌ¡A¤uµ{®v¡AÅU°Ý¡Aª«·~ºÞ²z¹F¹FIAQ¼Ð·Ç¤Î¸`¯àªº®ÄªG¡C

Ecofresh ERV ±N«Ç¤º¦Ã¿BªºªÅ®ð»P«Ç¥~ªº·sÂAªÅ®ð¶i¦æ¥æ´«,¨Ã±q±Æ©ñªºªÅ®ð¤¤¦^¦¬¯à¶q°ª¹F80%¡C¦^¦¬ªº¯à¶q¥Î©ó¹ï¨Ñµ¹ªºªÅ®ð¶i¦æ¹w³B²z¡]¹w§N/¹w¼ö¡^,¦]¦¹´î¤Ö¤F¹ï·s­·³B²z©Ò»Ýªº¯à¶q¡A¨Ï±o¥H¸û§Cªº¦¨¥»±a¤J§ó¦hªº·sÂAªÅ®ð¦¨¬°¥i¯à¡C

¦w¸Ë
Ecofresh ERV¦³§U©ó´î¤Ö·s¦Ñ«Ø¿v¤¤ªÅ½Õ§ë¸ê¤Î¹B¦æ¶O¥Î¡C
¯à¶qªº¦^¦¬¬O³q¹L¯à¶q¦^¦¬Âà½ü¦b¨âªÑ¤è¦V¬Û¤Ïªº®ð¬y±Æ®ð©M·s­·¤§¶¡½wºCªº±ÛÂà¡A±q¸û§N®ð¬y¤¤§l¦¬Åã¼ö©M¼ç¼ö¨ÃÄÀ©ñ¨ì·x®ð¬y¤¤¡C


Ecofresh¬ð¥X¯SÂI

¥i¿ï¾Ü©Ê¡XEcofresh ERVªº®Ö¤ß Ecofresh Âà½ü¦³±M§Q§Þ³Nªº¯S¯Å Ecosorb-340 §@°®À꾯¡A¥i¥H°£µß©MªÅ®ð¦Ã¬V¿ï¾Ü§lªþ¡CEcosorb-340¶È¤¹³\¤ô¤À¤l³q¹L¡A©Úµ´¥ô¦ó¥æ¤e¦Ã¬V¡C¦]¦¹¡A¦Ã¬Vª«©l²×¦s¯d¦b±Æ©ñ®ð¤¤¡A¤£·|¶i¤J·s­·ºÞ¸ô.

°ªÂX´²²v¡XEcosorb-340¬O°ª¿ï¾Ü©Ê©M°ªÂX´²²vªº§¹¬ü²Õ¦X

µ²ºc¨c©T¡X²{¥N¤Æ½L¶§Þ³N©MÖß±µ§Þ³N¨Ï Ecofresh ¨ã¦³¯S§O°ªªºµ²ºc±j«×

°ª©ß¥úªºªí­±¡X¡Xª½®|1000mmªºÂà½üªºÁa¦V©M®|¦V²¾°Ê°¾®t¤£¶W¹L1mm

¬Û¦PªºÅã¼ö/¼ç¼ö§l¦¬¯à¤O

°®À꾯¶î¼hªº«~½è,«p«×,ÄY®æ±±¨î°ª¤ô¤ÀÂX´²²v¡A«OÃÒ¦b¼sÁ諸À³¥Î½d³òùئ³¬Ûµ¥ªºÅã¼ö©M¼ç¼ö§l¦¬¯à¤O

³Ð·sªº³]­p¡X¡X´£¨Ñ¦hºØ¿ï¾Ü¡C¦³©³³¡¶}¤f[BO]¡A°¼­±¶}¤f[SO],¤Î©Ò¦³°¼­±¶}¤f[AO]ªº«¬¦¡¥i¨Ñ¿ï¾Ü

¯à¶q¦A¥Í³q­·¾÷ªºÀuÂI:

  • À°§U¹F¨ì1AQ¼Ð·Ç
  • §ïµ½«Ç¤ºÀã«×¤ô·Ç
  • ´î¤Ö¯à¶q®ø¯Ó
  • ­°§CªÅ½Õ¹B¦æ¦¨¥»¡]¥Ñ©ó­°§C¤F«Ç¥~·s­·ªºÀã«×¡^
  • ±M¬°ªï¦X¥«³õ»Ý¨D¦Ó³]­pªº§Cºû­×²vªº¸gÀÙ«¬¾÷¾¹
  • ¾A¦X¦Ñ«Ø¿vªº¨t²Î§ï³y
    ­@¥Î©Ê±j¡A©Ê¯àÀu²§¡A¤£©ö¦¾·l
  • ¯à¾AÀ³¼ö±a®ð­Ô

Ecofresh Energy Recovery Ventilator (ERV)... Fresh Air solution from the Airgineers

Ecofresh Energy Recovery Ventilators are equipped with Ecofresh Heat Recovery Wheels; capable of recovering more than 65% of each sensible and latent energy from the stale exhaust air and transferring it to the fresh outside air. The rotating wheel transfers the sensible and latent energy between the counter flowing exhaust and supply air and in the process preconditions (cool/heat/dehumidify/humidify) the fresh air.

An Ecofresh ERV helps to meet ASHRAE 62.1.2001 specified ventilation rates without increasing the air conditioning tonnage, saving capital and operating costs considerably.

Available in five models, Ecofresh ERVs address the basic requirements of a commercial energy recovery ventilator including -

• High energy transfer efficiency (both sensible and latent)
  (Making it the ideal choice in tropical regions as India)

• No cross contamination - Cross contamination between air streams limited to an absolute minimum with molecular sieve 3Å* (Ecosorb 300) coated energy recovery Wheels.

• Economical first cost

• Low operating costs
• Low maintenance

Ecofresh ERVs are the preferred option in S.E. Asia, West Asia, Middle East and Far East, Africa, Indian Subcontinent, CIS Countries, New Zealand and Australia.

The Ecofresh rotor is the first choice of OEMs in N.America, Japan and Europe.


¡@

¡@

FEATURES HIGHLIGHTS
Incorporates High Performance Ecofresh Total Energy Recovery Wheel in Aluminium, coated with Molecular Sieve 3Å for limiting cross contamination.
Efficient uptake of both sensible and latent energy each being more than 65%.
CNC fabricated cabinet type units in sheet steel construction.
Powder coated to world-class finish in siemens grey shade/off white leather finish.
Very low noise levels to meet advanced installation requirements.
Removable and washable Synthetic pre filters.
Large panel opening for easy access to filters and inspection of other components.
Provided with factory set purge.
Casing insulated with 19 mm close cells high density insulation to prevent condensation of moisture on exteriors or interiors of the unit.
Provided with metalic collars for duct connection.
Compact models, easy to install, operate and maintain.
Feather touch brush seals minimize cross contamination & ensure long life.

SPECIFICATION - ERV - 250/500
¡@
Model Supply Air Flow
(CMH)
Exhaust Air Flow
(CMH)
Dimensions in mm
(Excluding Base Frame)
Approx Shipping
Wt. in Kg
Noise Level
(dbA)
AC Power Source

Efficiency
Recovery

L W H
ERV-250 250 250
850
535
560
65
45**
230V/1Ph/50Hz
>65%
ERV-500
500 500 950 615 560
75
45** 230V/1Ph/50Hz
>65%


SPECIFICATION - ERV - 850

Model Supply Air Flow
(CMH)
Exhaust Air Flow
(CMH)
Dimensions in mm
(Excluding Base Frame)
Approx Shipping
Wt. in Kg
Noise Level
(dbA)
AC Power Source

Efficiency
Recovery

L W H
ERV-850 850 850
1150
655
575
90
45**
230V/1Ph/50Hz
>65%


SPECIFICATION - ERV - 1200/1700

Model Supply Air Flow
(CMH)
Exhaust Air Flow
(CMH)
Dimensions in mm
(Excluding Base Frame)
Approx Shipping
Wt. in Kg
Noise Level
(dbA)
AC Power Source

Efficiency
Recovery

L W H
ERV-1200 1200 1200
1450
1050
560
160
45**
230V/1Ph/50Hz
>65%
ERV-1700
1700 1700 1630 1100 560
180
45**
230V/1Ph/50Hz
>65%

** Measured at 3m distance (at 90o) when unit is ducted.
¡@

Application : Hospitality Industries

Energy conversation in Aircond Space using Enthalpy wheels

Indoor Air Quality -ASHRAE Standard

Indoor Air Quality -Issues at stake

New vent standards for IAQ vs Energy Conversation -Enthalpy Wheels meet the challenge

Treating Fresh Air Options and uses

Managing Aircon and needs of IAQ Cost effectively in hotels

IAP- New challenges for Designers

Back to Bry Air Product Page

Back to Product Page

Home  Contact Us Products

Room 1019, Nan Fung Comm. Ctr., 264-298 Castle Peak Road, Tsuen Wan, N.T. Hong Kong

香港新界青山道264-298号南豐商業中心1019

Tel 电話: (852) 2611-7376   Fax 傳真 : (852) 2617-5716   E-Mail电郵 : envirohk@netvigator.com